Prolonged hyperoxia, as may be used to treat patients with severe hypoxemia, can lead to lung injury, respiratory failure, and death. Resident mast cells play important roles in regulating the lung response to changing environmental conditions, as evidenced by their roles in asthma and airway hyperresponsiveness. In this study we evaluated the effect of prolonged hyperoxia on the number and distribution of mast cells in the rat lung. In rats maintained in normoxia, mast cells were distributed primarily in the loose connective tissue surrounding large bronchioles and vessels of the lung. In rats exposed to normobaric hyperoxia for 72 hr, mast cell number in lung sections increased significantly, and mast cells were found preferentially accumulated around vessels throughout the lung. Notably, mast cells around smaller vessels were abundant in hyperoxic lungs but rare in normoxic lungs. Also, mast cells were increased in the pleura of lungs exposed to hyperoxia. These changes in mast cell number and distribution in response to hyperoxia were evident in aged (22-month-old) rats as well as young (3-month-old) rats. As mast cell-derived mediators have many effects, e.g., on vascular leak and vascular tone, positioning of increased mast cell numbers throughout the lung vasculature may be an important contributor to changes in lung function subsequent to persistent hyperoxia.

Prolonged Exposure to Hyperoxia increases perivascular mast cells in rat lung

DI GIULIO, Camillo
2006-01-01

Abstract

Prolonged hyperoxia, as may be used to treat patients with severe hypoxemia, can lead to lung injury, respiratory failure, and death. Resident mast cells play important roles in regulating the lung response to changing environmental conditions, as evidenced by their roles in asthma and airway hyperresponsiveness. In this study we evaluated the effect of prolonged hyperoxia on the number and distribution of mast cells in the rat lung. In rats maintained in normoxia, mast cells were distributed primarily in the loose connective tissue surrounding large bronchioles and vessels of the lung. In rats exposed to normobaric hyperoxia for 72 hr, mast cell number in lung sections increased significantly, and mast cells were found preferentially accumulated around vessels throughout the lung. Notably, mast cells around smaller vessels were abundant in hyperoxic lungs but rare in normoxic lungs. Also, mast cells were increased in the pleura of lungs exposed to hyperoxia. These changes in mast cell number and distribution in response to hyperoxia were evident in aged (22-month-old) rats as well as young (3-month-old) rats. As mast cell-derived mediators have many effects, e.g., on vascular leak and vascular tone, positioning of increased mast cell numbers throughout the lung vasculature may be an important contributor to changes in lung function subsequent to persistent hyperoxia.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/110906
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact