A scaled-up version of the 6–8 Kwai-type multianvil apparatus has been developed at the Bayerisches Geoinstitut for operation over ranges of pressure and temperature attainable in conventional systems but with much larger sample volumes. This split-cylinder multianvil system is used with a hydraulic press that can generate loads of up to 5000 t (50 MN). The six tool-steel outer-anvils define a cubic cavity of 100mmedge-length in which eight 54mmtungsten carbide cubic inner-anvils are compressed. Experiments are performed using Cr2O3-doped MgO octahedra and pyrophyllite gaskets. Pressure calibrations at room temperature and high temperature have been performed with 14/8, 18/8, 18/11, 25/17 and 25/15 OEL/TEL (octahedral edge-length/anvil truncation edge-length, in millimetre) configurations. All configurations tested reach a limiting plateau where the sample-pressure no longer increases with applied load. Calibrations with different configurations show that greater sample-pressure efficiency can be achieved by increasing the OEL/TEL ratio. With the 18/8 configuration the GaP transition is reached at a load of 2500 t whereas using the 14/8 assembly this pressure cannot be reached even at substantially higher loads.With an applied load of 2000 t the 18/8 can produce MgSiO3 perovskite at 1900 ◦C with a sample volume of ∼20mm3, compared with <3mm3 in conventional multianvil systems at the same conditions. The large octahedron size and use of a stepped LaCrO3 heater also results in significantly lower thermal gradients over the sample.

A new large-volume multianvil system

POE, Brent Takashi;
2004-01-01

Abstract

A scaled-up version of the 6–8 Kwai-type multianvil apparatus has been developed at the Bayerisches Geoinstitut for operation over ranges of pressure and temperature attainable in conventional systems but with much larger sample volumes. This split-cylinder multianvil system is used with a hydraulic press that can generate loads of up to 5000 t (50 MN). The six tool-steel outer-anvils define a cubic cavity of 100mmedge-length in which eight 54mmtungsten carbide cubic inner-anvils are compressed. Experiments are performed using Cr2O3-doped MgO octahedra and pyrophyllite gaskets. Pressure calibrations at room temperature and high temperature have been performed with 14/8, 18/8, 18/11, 25/17 and 25/15 OEL/TEL (octahedral edge-length/anvil truncation edge-length, in millimetre) configurations. All configurations tested reach a limiting plateau where the sample-pressure no longer increases with applied load. Calibrations with different configurations show that greater sample-pressure efficiency can be achieved by increasing the OEL/TEL ratio. With the 18/8 configuration the GaP transition is reached at a load of 2500 t whereas using the 14/8 assembly this pressure cannot be reached even at substantially higher loads.With an applied load of 2000 t the 18/8 can produce MgSiO3 perovskite at 1900 ◦C with a sample volume of ∼20mm3, compared with <3mm3 in conventional multianvil systems at the same conditions. The large octahedron size and use of a stepped LaCrO3 heater also results in significantly lower thermal gradients over the sample.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/112542
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 155
  • ???jsp.display-item.citation.isi??? 144
social impact