his paper presents a study on the evaluation of the static performance of a glass fiber-reinforced polymer (GFRP) bridge deck that was installed in O'Fallon Park over Bear Creek west of the City of Denver. The bridge deck has a sandwich panel configuration, consisting of two stiff faces separated by a light-weight honeycomb core. The deck was manufactured using a hand lay-up technique. To assist the preliminary design of the deck, the stiffness and load-carrying capacities of four approximately 330 mm (13 in.) wide GFRP beam specimens were evaluated, The crushing capacity of the panel was also examined by subjecting four 330 X 305 X 190 mm (13 X 12 X 7.5 in.) specimens to compression tests. The experimental data were analyzed and compared to results obtained from analytical and finite element models, which have been used to enhance the understanding of the experimental observations. The failure of all four beams was caused by the delamination of the top faces. In spite of the scatter of the tests results, the beams showed good shear strengths, at the face-to-core interface as compared to similar panels evaluated in prior studies

Evaluation of GFRP Honeycomb Beams for the O'Fallon Park Bridge

CAMATA, Guido;
2005-01-01

Abstract

his paper presents a study on the evaluation of the static performance of a glass fiber-reinforced polymer (GFRP) bridge deck that was installed in O'Fallon Park over Bear Creek west of the City of Denver. The bridge deck has a sandwich panel configuration, consisting of two stiff faces separated by a light-weight honeycomb core. The deck was manufactured using a hand lay-up technique. To assist the preliminary design of the deck, the stiffness and load-carrying capacities of four approximately 330 mm (13 in.) wide GFRP beam specimens were evaluated, The crushing capacity of the panel was also examined by subjecting four 330 X 305 X 190 mm (13 X 12 X 7.5 in.) specimens to compression tests. The experimental data were analyzed and compared to results obtained from analytical and finite element models, which have been used to enhance the understanding of the experimental observations. The failure of all four beams was caused by the delamination of the top faces. In spite of the scatter of the tests results, the beams showed good shear strengths, at the face-to-core interface as compared to similar panels evaluated in prior studies
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/131676
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact