BACKGROUND AND PURPOSE: Leukoaraiosis (LA) has been defined as low attenuation areas involving only the periventricular white matter, in the mild form, and extending to the subcortical region in the severe form. This study evaluates, in elderly patients, if brain computed tomography (CT) evidence of LA significantly correlates with the findings of 24-hour, blood pressure monitoring. METHODS: Sixtysix neurologically nondiseased elderly patients underwent CT examination of the brain and 24-hour ambulatory blood pressure monitoring. The patients were divided in two groups (patients with none-to-mild LA in group 1; patients with severe LA in group 2) based on CT findings evaluated at level of foramina of Monro, body of lateral ventricles, and frontoparietal white matter (centrum semiovale). CT findings were compared with main 24-hour ambulatory blood pressure monitoring results (systolic and diastolic blood pressure and heart rate values).

Correlation between computed tomography findings of leukoaraiosis and 24-hour blood pressure variability in elderly subjects

TARTARO, Armando;DI IORIO, Angelo;ABATE, Giuseppe;BONOMO, Lorenzo
1999-01-01

Abstract

BACKGROUND AND PURPOSE: Leukoaraiosis (LA) has been defined as low attenuation areas involving only the periventricular white matter, in the mild form, and extending to the subcortical region in the severe form. This study evaluates, in elderly patients, if brain computed tomography (CT) evidence of LA significantly correlates with the findings of 24-hour, blood pressure monitoring. METHODS: Sixtysix neurologically nondiseased elderly patients underwent CT examination of the brain and 24-hour ambulatory blood pressure monitoring. The patients were divided in two groups (patients with none-to-mild LA in group 1; patients with severe LA in group 2) based on CT findings evaluated at level of foramina of Monro, body of lateral ventricles, and frontoparietal white matter (centrum semiovale). CT findings were compared with main 24-hour ambulatory blood pressure monitoring results (systolic and diastolic blood pressure and heart rate values).
File in questo prodotto:
File Dimensione Formato  
Tartaro et al, 1999 J Stroke and Cerebr Dis.pdf

Solo gestori archivio

Tipologia: Documento in Post-print
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/215578
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 16
social impact