Purpose: Resonance frequency analysis (RFA) is a quantitative method for the measurement of implant stability. Information about the significance of RFA measurements and the relationship between RFA values and implant osseointegration, success, or failure is important from a clinical point of view. In a previous study the authors observed a strong correlation between RFA values and mineralized bone-implant contact percentage in implants retrieved after 6 months. The aim of the present histologic and histomorphometric study was to determine whether the same correlation existed at earlier time points, specifically in implants retrieved after 4 or 8 weeks. Materials and Methods: Sixteen implants, all with a sandblasted and acid-etched surface, were evaluated in the present study. The implants were retrieved for different reasons after 4 or 8 weeks of healing with a 5-mm trephine bur and immersed in 10% buffered formalin to be processed for histology. Results: A statistically insignificant correlation was detected between RFA values and mineralized bone-implant contact percentage (P = .5502) using the Friedman and Spearman tests. Conclusion: RFA should reflect the bone anchorage of the implant; however, the relationship between bone structure and RFA is not fully understood.

Mineralized bone-implant contact and implant stability quotient in 16 human implants retrieved after early healing periods: a histologic and histomorphometric evaluation.

PERROTTI, Vittoria;PIATTELLI, Adriano;IEZZI, GIOVANNA
2010-01-01

Abstract

Purpose: Resonance frequency analysis (RFA) is a quantitative method for the measurement of implant stability. Information about the significance of RFA measurements and the relationship between RFA values and implant osseointegration, success, or failure is important from a clinical point of view. In a previous study the authors observed a strong correlation between RFA values and mineralized bone-implant contact percentage in implants retrieved after 6 months. The aim of the present histologic and histomorphometric study was to determine whether the same correlation existed at earlier time points, specifically in implants retrieved after 4 or 8 weeks. Materials and Methods: Sixteen implants, all with a sandblasted and acid-etched surface, were evaluated in the present study. The implants were retrieved for different reasons after 4 or 8 weeks of healing with a 5-mm trephine bur and immersed in 10% buffered formalin to be processed for histology. Results: A statistically insignificant correlation was detected between RFA values and mineralized bone-implant contact percentage (P = .5502) using the Friedman and Spearman tests. Conclusion: RFA should reflect the bone anchorage of the implant; however, the relationship between bone structure and RFA is not fully understood.
File in questo prodotto:
File Dimensione Formato  
MINERALIZED BONE IMPLANT CONTACT AND IMPLANT STABILITY QUOTIENT JOMI JAN 2010.PDF

Solo gestori archivio

Tipologia: PDF editoriale
Dimensione 230.39 kB
Formato Adobe PDF
230.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/225895
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 32
social impact