PURPOSE: Aim of this study was to evaluate the histological and histomorphometrical differences at the marginal bone level with the use of 2 different implant-abutment assembly designs (the traditional External Hexagon and the Morse Cone tapered connections). METHODS: Nine Morse Cone and 9 External Hexagon implants were inserted in 6 mongrel dogs. The Morse Cone implants were installed 2 mm below the crestal bone level, whereas the External Hexagon flush. The implants were retrieved after 2 months. Mean distance between the original level of coronal bone to the top of the implant and the mean distance between the top of the implant and the first bone-to-implant contact (fBIC) were recorded. RESULTS: No significant differences were found when the mean distance between the original level of coronal bone to the top of the implant was evaluated; however, there were statistically significant differences in the mean distances between the top of the implants and fBIC, suggesting a smaller amount of bone loss or remodeling in the Morse Cone compared to the External Hexagon group.

Comparative Histological and Histomorphometrical Evaluation of Marginal Bone Resorption Around External Hexagon and Morse Cone Implants: An Experimental Study in Dogs

PIATTELLI, Adriano;PERROTTI, Vittoria;IEZZI, GIOVANNA
2014-01-01

Abstract

PURPOSE: Aim of this study was to evaluate the histological and histomorphometrical differences at the marginal bone level with the use of 2 different implant-abutment assembly designs (the traditional External Hexagon and the Morse Cone tapered connections). METHODS: Nine Morse Cone and 9 External Hexagon implants were inserted in 6 mongrel dogs. The Morse Cone implants were installed 2 mm below the crestal bone level, whereas the External Hexagon flush. The implants were retrieved after 2 months. Mean distance between the original level of coronal bone to the top of the implant and the mean distance between the top of the implant and the first bone-to-implant contact (fBIC) were recorded. RESULTS: No significant differences were found when the mean distance between the original level of coronal bone to the top of the implant was evaluated; however, there were statistically significant differences in the mean distances between the top of the implants and fBIC, suggesting a smaller amount of bone loss or remodeling in the Morse Cone compared to the External Hexagon group.
File in questo prodotto:
File Dimensione Formato  
2014-ARAUJO-IMPLANT DENT.pdf

Solo gestori archivio

Tipologia: Documento in Post-print
Dimensione 550.9 kB
Formato Adobe PDF
550.9 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/641348
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 26
social impact