Phosphatase and tensin homolog (PTEN) loss is frequently observed in NSCLC and associated with both phosphoinositide 3-kinase activation and tumoral immunosuppression. PTEN immunohistochemistry is a valuable readout, but lacks standardized staining protocol and cutoff value. METHODS: After an external quality assessment using SP218, 138G6 and 6H2.1 anti-PTEN antibodies, scored on webbook and tissue microarray, the European Thoracic Oncology Platform cohort samples (n = 2245 NSCLC patients, 8980 tissue microarray cores) were stained with SP218. All cores were H-scored by pathologists and by computerized pixel-based intensity measurements calibrated by pathologists. RESULTS: All three antibodies differentiated six PTEN+ versus six PTEN- cases on external quality assessment. For 138G6 and SP218, high sensitivity and specificity was found for all H-score threshold values including prospectively defined 0, calculated 8 (pathologists), and calculated 5 (computer). High concordance among pathologists in setting computer-based intensities and between pathologists and computer in H-scoring was observed. Because of over-integration of the human eye, pixel-based computer H-scores were overall 54% lower. For all cutoff values, PTEN- was associated with smoking history, squamous cell histology, and higher tumor stage (p < 0.001). In adenocarcinomas, PTEN- was associated with poor survival.

Computer-Based Intensity Measurement Assists Pathologists in Scoring Phosphatase and Tensin Homolog Immunohistochemistry — Clinical Associations in NSCLC Patients of the European Thoracic Oncology Platform Lungscape Cohort

Marchetti A.;
2018-01-01

Abstract

Phosphatase and tensin homolog (PTEN) loss is frequently observed in NSCLC and associated with both phosphoinositide 3-kinase activation and tumoral immunosuppression. PTEN immunohistochemistry is a valuable readout, but lacks standardized staining protocol and cutoff value. METHODS: After an external quality assessment using SP218, 138G6 and 6H2.1 anti-PTEN antibodies, scored on webbook and tissue microarray, the European Thoracic Oncology Platform cohort samples (n = 2245 NSCLC patients, 8980 tissue microarray cores) were stained with SP218. All cores were H-scored by pathologists and by computerized pixel-based intensity measurements calibrated by pathologists. RESULTS: All three antibodies differentiated six PTEN+ versus six PTEN- cases on external quality assessment. For 138G6 and SP218, high sensitivity and specificity was found for all H-score threshold values including prospectively defined 0, calculated 8 (pathologists), and calculated 5 (computer). High concordance among pathologists in setting computer-based intensities and between pathologists and computer in H-scoring was observed. Because of over-integration of the human eye, pixel-based computer H-scores were overall 54% lower. For all cutoff values, PTEN- was associated with smoking history, squamous cell histology, and higher tumor stage (p < 0.001). In adenocarcinomas, PTEN- was associated with poor survival.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/712067
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact