Purpose: The design and performance of a novel head coil setup for (Formula presented.) P spectroscopy at ultra-high field strengths (7T) is presented. The described system supports measurements at both the (Formula presented.) H and (Formula presented.) P resonance frequencies. Methods: The novel coil consists of 2, actively detunable, coaxial birdcage coils to give homogeneous transmit, combined with a double resonant 30 channel receive array. This allows for anatomical imaging combined with (Formula presented.) P acquisitions over the whole head, without changing coils or disturbing the subject. A phosphate buffer phantom and 3 healthy volunteers were scanned with a pulse acquire CSI sequence using both the novel array coil and a conventional transceiver birdcage. Four different methods of combining the array channels were compared at 3 different levels of SNR. Results: The novel coil setup delivers significantly increased (Formula presented.) P SNR in the peripheral regions of the brain, reaching up to factor 8, while maintaining comparable performance relative to the birdcage in the center. Conclusions: The new system offers the potential to acquire whole brain (Formula presented.) P MRSI with superior signal relative to the standard options.

Whole brain 31P MRSI at 7T with a dual-tuned receive array

Wise R. G.
2020-01-01

Abstract

Purpose: The design and performance of a novel head coil setup for (Formula presented.) P spectroscopy at ultra-high field strengths (7T) is presented. The described system supports measurements at both the (Formula presented.) H and (Formula presented.) P resonance frequencies. Methods: The novel coil consists of 2, actively detunable, coaxial birdcage coils to give homogeneous transmit, combined with a double resonant 30 channel receive array. This allows for anatomical imaging combined with (Formula presented.) P acquisitions over the whole head, without changing coils or disturbing the subject. A phosphate buffer phantom and 3 healthy volunteers were scanned with a pulse acquire CSI sequence using both the novel array coil and a conventional transceiver birdcage. Four different methods of combining the array channels were compared at 3 different levels of SNR. Results: The novel coil setup delivers significantly increased (Formula presented.) P SNR in the peripheral regions of the brain, reaching up to factor 8, while maintaining comparable performance relative to the birdcage in the center. Conclusions: The new system offers the potential to acquire whole brain (Formula presented.) P MRSI with superior signal relative to the standard options.
File in questo prodotto:
File Dimensione Formato  
2019_Rowland_MRM.pdf

Solo gestori archivio

Descrizione: Articolo principale
Tipologia: PDF editoriale
Dimensione 1.64 MB
Formato Adobe PDF
1.64 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/716942
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 9
social impact