We have developed a novel method to measure human cardiac pulse at a distance. It is based on the information contained in the thermal signal emitted from major superficial vessels. This signal is acquired through a highly sensitive thermal imaging system. Temperature on the vessel is modulated by pulsative blood flow. To compute the frequency of modulation (pulse), we extract a line-based region along the vessel. Then, we apply fast Fourier transform (FFT) to individual points along this line of interest to capitalize on the pulse’s thermal propagation effect. Finally, we use an adaptive estimation function on the average FFT outcome to quantify the pulse. We have carried out experiments on a data set of 34 subjects and compared the pulse computed from our thermal signal analysis method to concomitant ground-truth measurements obtained through a standard contact sensor (piezo-electric transducer). The performance of the new method ranges from 88.52% to 90.33% depending on the clarity of the vessel’s thermal imprint. To the best of our knowledge, it is the first time that cardiac pulse has been measured several feet away from a subject with passive means.

Contact-free measurement of cardiac pulse based on the analysis of thermal imagery

MERLA, Arcangelo;
2007-01-01

Abstract

We have developed a novel method to measure human cardiac pulse at a distance. It is based on the information contained in the thermal signal emitted from major superficial vessels. This signal is acquired through a highly sensitive thermal imaging system. Temperature on the vessel is modulated by pulsative blood flow. To compute the frequency of modulation (pulse), we extract a line-based region along the vessel. Then, we apply fast Fourier transform (FFT) to individual points along this line of interest to capitalize on the pulse’s thermal propagation effect. Finally, we use an adaptive estimation function on the average FFT outcome to quantify the pulse. We have carried out experiments on a data set of 34 subjects and compared the pulse computed from our thermal signal analysis method to concomitant ground-truth measurements obtained through a standard contact sensor (piezo-electric transducer). The performance of the new method ranges from 88.52% to 90.33% depending on the clarity of the vessel’s thermal imprint. To the best of our knowledge, it is the first time that cardiac pulse has been measured several feet away from a subject with passive means.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/107799
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 335
  • ???jsp.display-item.citation.isi??? 266
social impact