Current literature reports that surface acid etching can improve bone--implant contact (BIC). The aim of this study was to evaluate the differences of BIC between acid-etched (Osseotite) and machined surface implants. Six white New Zealand mature rabbits were used in the present investigation. Each rabbit received two implants, specially made with two surfaces on it (one acid-etched and one machined) into each tibia. A total of 24 implants were inserted. Two animals each were killed at 15, 30, and 60 days after implant placement. Histomorphometry of BIC was statistically evaluated. The acid-etched surfaces showed a greater bone contact percentage than the machined ones during the early phase of healing (15 days), which was not statistically significant. On the other hand, after 30 and 60 days, the differences of BIC between acid-etched and machined surfaces were statistically significant. The acid-etched surface appears to improve BIC at a later stage of healing.
Bone contact around osseointegrated implants: a histologic study of acid-etched and machined surfaces.
CELLETTI, Renato;TRAINI, TONINO;PERROTTI, Vittoria;PIATTELLI, Adriano
2006-01-01
Abstract
Current literature reports that surface acid etching can improve bone--implant contact (BIC). The aim of this study was to evaluate the differences of BIC between acid-etched (Osseotite) and machined surface implants. Six white New Zealand mature rabbits were used in the present investigation. Each rabbit received two implants, specially made with two surfaces on it (one acid-etched and one machined) into each tibia. A total of 24 implants were inserted. Two animals each were killed at 15, 30, and 60 days after implant placement. Histomorphometry of BIC was statistically evaluated. The acid-etched surfaces showed a greater bone contact percentage than the machined ones during the early phase of healing (15 days), which was not statistically significant. On the other hand, after 30 and 60 days, the differences of BIC between acid-etched and machined surfaces were statistically significant. The acid-etched surface appears to improve BIC at a later stage of healing.File | Dimensione | Formato | |
---|---|---|---|
Journal of Long-Term Effects of Medical Implants Celletti.pdf
Solo gestori archivio
Tipologia:
PDF editoriale
Dimensione
2.37 MB
Formato
Adobe PDF
|
2.37 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.