Background: The biologic behavior, i.e., the degradation of hydroxyapatite (HA) in the human body, is of relevance for clinicians. The present investigation is a long-term (20-year) histologic and histomorphometric evaluation of dense HA used in postextraction sockets. Methods: Dense HA particles were used in a patient in postextraction alveolar sockets to maintain the alveolar ridge height. The patient returned after 20 years for implant treatment. A ridge remodeling was necessary during implant insertion surgery, and the HA/bone tissue was harvested with bone-cutting forceps from the canine and premolar area. The specimen was processed for histology and histomorphometry at the Implant Retrieval Centre, Dental School, University of Chieti-Pescara. Results: Most of the particles (56%) were surrounded partially by bone, whereas some particles (39%) were surrounded completely. At higher magnification, bone was in close contact with the particles, and neither gaps nor flbrous tissues were present at the bone-biomaterial interface. Microscopically, the particles had a dense appearance. In only a few fields, it was possible to observe that the outer part of some particles had detached from the original particles' surface. Histomorphometry showed that bone represented 25.4% +/- 3.2%, marrow spaces represented 41.3% +/- 5.2%, and residual HA particles represented 38.1% +/- 4.1%. Conclusions: Intimate binding between bone and HA particles was present after a long-term implantation period (20 years). The fact that HA particles were surrounded closely by bone is very promising for the long-term stability of the augmentation.

Dense hydroxyapatite inserted into post-extraction sockets. A histologic and histomorphometric 20-year case report.

PIATTELLI, Adriano;PERROTTI, Vittoria;IEZZI, GIOVANNA
2008-01-01

Abstract

Background: The biologic behavior, i.e., the degradation of hydroxyapatite (HA) in the human body, is of relevance for clinicians. The present investigation is a long-term (20-year) histologic and histomorphometric evaluation of dense HA used in postextraction sockets. Methods: Dense HA particles were used in a patient in postextraction alveolar sockets to maintain the alveolar ridge height. The patient returned after 20 years for implant treatment. A ridge remodeling was necessary during implant insertion surgery, and the HA/bone tissue was harvested with bone-cutting forceps from the canine and premolar area. The specimen was processed for histology and histomorphometry at the Implant Retrieval Centre, Dental School, University of Chieti-Pescara. Results: Most of the particles (56%) were surrounded partially by bone, whereas some particles (39%) were surrounded completely. At higher magnification, bone was in close contact with the particles, and neither gaps nor flbrous tissues were present at the bone-biomaterial interface. Microscopically, the particles had a dense appearance. In only a few fields, it was possible to observe that the outer part of some particles had detached from the original particles' surface. Histomorphometry showed that bone represented 25.4% +/- 3.2%, marrow spaces represented 41.3% +/- 5.2%, and residual HA particles represented 38.1% +/- 4.1%. Conclusions: Intimate binding between bone and HA particles was present after a long-term implantation period (20 years). The fact that HA particles were surrounded closely by bone is very promising for the long-term stability of the augmentation.
File in questo prodotto:
File Dimensione Formato  
2008 DENSE HA 20y-J PERIO.pdf

accesso aperto

Tipologia: Documento in Post-print
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/137962
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 27
social impact