After preoperative assessment revealed anomalous posterior vitreous detachment, a 75-year-old woman affected with retinal detachment due to macular hole was scheduled to undergo the posterior episcleral buckling procedure. Preoperative microperimetry showed unstable eccentric fixation with a dense scotoma within the central 8°. One month postoperatively, best-corrected visual acuity increased from 1.70 to 0.88 logarithm of the minimum angle of resolution. Ultrasonography and optical coherence tomography revealed the indentation of the posterior scleral profile due to the buckle. The retina appeared fully attached and a macular hole with flattened edges was still detectable. Microperimetry showed stable central fixation with recovery of retinal sensitivity within the central 2°. Diagnostic imaging techniques guided the decision to use the posterior episcleral buckling procedure. Microperimetry was useful to explain vision improvement despite residual macular hole.

The role of diagnostic imaging techniques in the management of retinal detachment due to macular hole in high myopia.

CARPINETO, Paolo;DI ANTONIO, LUCA;NUBILE, MARIO;MASTROPASQUA, Leonardo
2009-01-01

Abstract

After preoperative assessment revealed anomalous posterior vitreous detachment, a 75-year-old woman affected with retinal detachment due to macular hole was scheduled to undergo the posterior episcleral buckling procedure. Preoperative microperimetry showed unstable eccentric fixation with a dense scotoma within the central 8°. One month postoperatively, best-corrected visual acuity increased from 1.70 to 0.88 logarithm of the minimum angle of resolution. Ultrasonography and optical coherence tomography revealed the indentation of the posterior scleral profile due to the buckle. The retina appeared fully attached and a macular hole with flattened edges was still detectable. Microperimetry showed stable central fixation with recovery of retinal sensitivity within the central 2°. Diagnostic imaging techniques guided the decision to use the posterior episcleral buckling procedure. Microperimetry was useful to explain vision improvement despite residual macular hole.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/169076
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact