Most of the histologic studies found in the literature on the peri-implant soft tissues have been done in animals and usually have been confined to mandibular implants fitted with healing or standard abutments. Few studies have investigated human peri-implant soft tissues. Moreover, the structure and dimensions of the peri-implant soft tissues in immediately loaded implants have not been investigated in depth. Human histologic data are valuable to validate animal models. This histologic and histomorphometric study evaluated the peri-implant soft tissues around three immediately loaded implants in humans. The implants were retrieved using a trephine and treated to obtain thin, ground sections. The sulcular epithelium was composed of approximately four to five layers of parakeratinized epithelial cells and had a length of approximately 1.2 to 1.3 mm. The junctional epithelium was composed of approximately three to four layers of epithelial cells and had a length of approximately 1.0 to 1.5 mm. Connective tissue attachment had a width of between 400 and 800 μm. Peri-implant collagen fibers, in the form of bundles (1- to 5-μm thick), began at the crestal bone and were oriented perpendicular to the abutment surface until 200 μm from the surface, where they became parallel running in several directions. Collagen fibers appeared to form a three-dimensional network around the abutment. No acute or chronic inflammatory cell infiltrate was present. Collagen fibers oriented in a perpendicular manner and in direct contact with the abutment surface were not observed in any of the specimens. This differentiated network of fibers may have clinical relevance as a mechanical protection of the underlying bone. These human histologic data are extremely valuable to validate and confirm those obtained from studies performed on animal models. Moreover, immediate loading of the implants did not compromise soft tissue integration.

Peri-implant collagen fibers around human Cone Morse connection implants under polarized light. A report of 3 cases

PIATTELLI, Adriano;SCARANO, Antonio;IEZZI, GIOVANNA
2012-01-01

Abstract

Most of the histologic studies found in the literature on the peri-implant soft tissues have been done in animals and usually have been confined to mandibular implants fitted with healing or standard abutments. Few studies have investigated human peri-implant soft tissues. Moreover, the structure and dimensions of the peri-implant soft tissues in immediately loaded implants have not been investigated in depth. Human histologic data are valuable to validate animal models. This histologic and histomorphometric study evaluated the peri-implant soft tissues around three immediately loaded implants in humans. The implants were retrieved using a trephine and treated to obtain thin, ground sections. The sulcular epithelium was composed of approximately four to five layers of parakeratinized epithelial cells and had a length of approximately 1.2 to 1.3 mm. The junctional epithelium was composed of approximately three to four layers of epithelial cells and had a length of approximately 1.0 to 1.5 mm. Connective tissue attachment had a width of between 400 and 800 μm. Peri-implant collagen fibers, in the form of bundles (1- to 5-μm thick), began at the crestal bone and were oriented perpendicular to the abutment surface until 200 μm from the surface, where they became parallel running in several directions. Collagen fibers appeared to form a three-dimensional network around the abutment. No acute or chronic inflammatory cell infiltrate was present. Collagen fibers oriented in a perpendicular manner and in direct contact with the abutment surface were not observed in any of the specimens. This differentiated network of fibers may have clinical relevance as a mechanical protection of the underlying bone. These human histologic data are extremely valuable to validate and confirm those obtained from studies performed on animal models. Moreover, immediate loading of the implants did not compromise soft tissue integration.
File in questo prodotto:
File Dimensione Formato  
2012- degidi et al- JPRD-Peri-Implant Collagen Fibers .pdf

Solo gestori archivio

Tipologia: Documento in Post-print
Dimensione 644.07 kB
Formato Adobe PDF
644.07 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/261485
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 35
social impact