INTRODUCTION:Lung cancer is the highest cause of mortality among tumor pathologies worldwide. There are no validated techniques for an early detection of pulmonary cancer lesions other than low-dose helical computed tomography scan. Unfortunately, this method has some negative effects. Recent studies have laid the basis for development of exosomes-based techniques to screen/diagnose lung cancers. As the isolation of circulating exosomes is a minimally invasive procedure, this technique opens new possibilities for diagnostic applications. METHODS:We used a first set of 30 plasma samples from as many patients, including 10 patients affected by lung adenocarcinomas, 10 with lung granulomas, and 10 healthy smokers matched for age and sex as negative controls. Wide-range microRNAs analysis (742 microRNAs) was performed by quantitative real time polymerase chain reaction. Data were compared on the basis of lesion characteristics, using WEKA software for statistics and modeling. Subsequently, selected microRNAs were evaluated on an independent larger group of samples (105 specimens: 50 lung adenocarcinomas, 30 lung granulomas, and 25 healthy smokers). RESULTS:This analysis led to the selection of four microRNAs to perform a screening test (miR-378a, miR-379, miR-139-5p, and miR-200b-5p), useful to divide population into two groups: nodule (lung adenocarcinomas + carcinomas) and non-nodule (healthy former smokers). Six microRNAs (miR-151a-5p, miR-30a-3p, miR-200b-5p, miR-629, miR-100, and miR-154-3p) were selected for a second test on the nodule population to discriminate between lung adenocarcinoma and granuloma. CONCLUSIONS:The screening test showed 97.5% sensitivity, 72.0% specificity, and area under the curve receiver operating characteristic of 90.8%. The diagnostic test had 96.0% sensitivity, 60.0% specificity, and area under the curve receiver operating characteristic of 76.0%. Further evaluation is needed to confirm the predictive power of these models on larger cohorts of samples.

microRNAs Derived from Circulating Exosomes as Noninvasive Biomarkers for Screening and Diagnosing Lung Cancer.

CAZZOLI, RICCARDO;BUTTITTA, Fiamma;DI NICOLA, MARTA;MALATESTA, SARA;MARCHETTI, Antonio;
2013-01-01

Abstract

INTRODUCTION:Lung cancer is the highest cause of mortality among tumor pathologies worldwide. There are no validated techniques for an early detection of pulmonary cancer lesions other than low-dose helical computed tomography scan. Unfortunately, this method has some negative effects. Recent studies have laid the basis for development of exosomes-based techniques to screen/diagnose lung cancers. As the isolation of circulating exosomes is a minimally invasive procedure, this technique opens new possibilities for diagnostic applications. METHODS:We used a first set of 30 plasma samples from as many patients, including 10 patients affected by lung adenocarcinomas, 10 with lung granulomas, and 10 healthy smokers matched for age and sex as negative controls. Wide-range microRNAs analysis (742 microRNAs) was performed by quantitative real time polymerase chain reaction. Data were compared on the basis of lesion characteristics, using WEKA software for statistics and modeling. Subsequently, selected microRNAs were evaluated on an independent larger group of samples (105 specimens: 50 lung adenocarcinomas, 30 lung granulomas, and 25 healthy smokers). RESULTS:This analysis led to the selection of four microRNAs to perform a screening test (miR-378a, miR-379, miR-139-5p, and miR-200b-5p), useful to divide population into two groups: nodule (lung adenocarcinomas + carcinomas) and non-nodule (healthy former smokers). Six microRNAs (miR-151a-5p, miR-30a-3p, miR-200b-5p, miR-629, miR-100, and miR-154-3p) were selected for a second test on the nodule population to discriminate between lung adenocarcinoma and granuloma. CONCLUSIONS:The screening test showed 97.5% sensitivity, 72.0% specificity, and area under the curve receiver operating characteristic of 90.8%. The diagnostic test had 96.0% sensitivity, 60.0% specificity, and area under the curve receiver operating characteristic of 76.0%. Further evaluation is needed to confirm the predictive power of these models on larger cohorts of samples.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/456687
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 173
  • Scopus 398
  • ???jsp.display-item.citation.isi??? 358
social impact