Oxyprenylated natural products were shown to exert in vitro and in vivo remarkable anti-cancer and anti-inflammatory effects. This paper describes a rapid, selective, and sensitive HPLC method with fluorescence detection for determination of 4'-geranyloxyferulic acid (GOFA) and its conjugate with l-nitroarginine methyl ester (GOFA-L-NAME) in mononuclear cells. Analytes were extracted from cells using methanol and eluted on a GraceSmart RP18 analytical column (250×4.6mm i.d., 5μm particle size) kept at 25°C. A mixture of formic acid 1% in water (A) and methanol (B) were used as mobile phase, at a flow-rate of 1.2mL/min in gradient elution. A fluorescence detector (excitation/emission wavelength of 319/398nm for GOFA and GOFA-L-NAME), was used for the two analytes. Calibration curves of GOFA and GOFA-L-NAME were linear over the concentration range of 1.0-50μg/mL, with correlation coefficients (r2)≥0.9995. Intra- and inter-assay precision do not exceed 6.8%. The accuracy was from 94% to 105% for quality control samples (2.0, 25.0 and 40μg/mL). The mean (RSD%) extraction recoveries (n=5) for GOFA and GOFA-L-NAME from spiked cells at 2.0, 25.0 and 40.0μg/mL were 92.4±1.5%, 94.7±0.9% and 93.8±1.1%, for GOFA and 95.3±1.2%, 94.8±1.0% and 93.9±1.3%, for GOFA-L-NAME. The limits of detection and quantification were 0.3μg/mL and 1.0μg/mL for GOFA and GOFA-L-NAME. This method was successfully applied to measure GOFA and GOFA-L-NAME concentrations in a mononuclear cells.

Quantitative profiling of 4'-geranyloxyferulic acid and its conjugate with L-nitroarginine methyl ester in mononuclear cells by high-performance liquid chromatography with fluorescence detection

Vito Alessandro Taddeo;Salvatore Genovese
;
Giuseppe Carlucci;Vincenzo Ferrone;Antonia Patruno;Alessio Ferrone;Serena Fiorito;Francesco Epifano
2017-01-01

Abstract

Oxyprenylated natural products were shown to exert in vitro and in vivo remarkable anti-cancer and anti-inflammatory effects. This paper describes a rapid, selective, and sensitive HPLC method with fluorescence detection for determination of 4'-geranyloxyferulic acid (GOFA) and its conjugate with l-nitroarginine methyl ester (GOFA-L-NAME) in mononuclear cells. Analytes were extracted from cells using methanol and eluted on a GraceSmart RP18 analytical column (250×4.6mm i.d., 5μm particle size) kept at 25°C. A mixture of formic acid 1% in water (A) and methanol (B) were used as mobile phase, at a flow-rate of 1.2mL/min in gradient elution. A fluorescence detector (excitation/emission wavelength of 319/398nm for GOFA and GOFA-L-NAME), was used for the two analytes. Calibration curves of GOFA and GOFA-L-NAME were linear over the concentration range of 1.0-50μg/mL, with correlation coefficients (r2)≥0.9995. Intra- and inter-assay precision do not exceed 6.8%. The accuracy was from 94% to 105% for quality control samples (2.0, 25.0 and 40μg/mL). The mean (RSD%) extraction recoveries (n=5) for GOFA and GOFA-L-NAME from spiked cells at 2.0, 25.0 and 40.0μg/mL were 92.4±1.5%, 94.7±0.9% and 93.8±1.1%, for GOFA and 95.3±1.2%, 94.8±1.0% and 93.9±1.3%, for GOFA-L-NAME. The limits of detection and quantification were 0.3μg/mL and 1.0μg/mL for GOFA and GOFA-L-NAME. This method was successfully applied to measure GOFA and GOFA-L-NAME concentrations in a mononuclear cells.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0731708516310974-main.pdf

Solo gestori archivio

Descrizione: Article
Tipologia: PDF editoriale
Dimensione 878.63 kB
Formato Adobe PDF
878.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/663365
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact