Background: To determine interobserver variability in clinical target volume (CTV) of supra-diaphragmatic Hodgkin's lymphoma. Materials and Methods: At the 2008 AIRO (Italian Society of Radiation Oncology) Meeting, the Radiation Oncology Department of Chieti proposed a multi-institutional contouring dummy-run of two cases of early stage supra-diaphragmatic Hodgkin's lymphoma after chemotherapy. Clinical history, diagnostics, and planning CT imaging were available on Chieti's radiotherapy website (www.radioterapia.unich.it). Participating centers were requested to delineate the CTV and submit it to the coordinating center. To quantify interobserver variability of CTV delineations, the total volume, craniocaudal, laterolateral, and anteroposterior diameters were calculated. Results: A total of 18 institutions for case A and 15 institutions for case B submitted the targets. Case A presented significant variability in total volume (range: 74.1-1,157.1 cc), craniocaudal (range: 6.5-22.5 cm; median: 16.25 cm), anteroposterior (range: 5.04-14.82 cm; median: 10.28 cm), and laterolateral diameters (range: 8.23-22.88 cm; median: 15.5 cm). Mean CTV was 464.8 cc (standard deviation: 280.5 cc). Case B presented significant variability in total volume (range: 341.8-1,662 cc), craniocaudal (range: 8.0-28.5 cm; median: 23 cm), anteroposterior (range: 7.9-1.8 cm; median: 11.1 cm), and laterolateral diameters (range: 12.9-24.0 cm; median: 18.8 cm). Mean CTV was 926.0 cc (standard deviation: 445.7 cc). Conclusion: This significant variability confirms the need to apply specific guidelines to improve contouring uniformity in Hodgkin's lymphoma.

Interobserver variability of clinical target volume delineation in supra-diaphragmatic Hodgkin's disease: A multi-institutional experience

GENOVESI, Domenico;VINCIGUERRA, ANNAMARIA;DI TOMMASO, MONICA;MARCHESE, RITA;
2011-01-01

Abstract

Background: To determine interobserver variability in clinical target volume (CTV) of supra-diaphragmatic Hodgkin's lymphoma. Materials and Methods: At the 2008 AIRO (Italian Society of Radiation Oncology) Meeting, the Radiation Oncology Department of Chieti proposed a multi-institutional contouring dummy-run of two cases of early stage supra-diaphragmatic Hodgkin's lymphoma after chemotherapy. Clinical history, diagnostics, and planning CT imaging were available on Chieti's radiotherapy website (www.radioterapia.unich.it). Participating centers were requested to delineate the CTV and submit it to the coordinating center. To quantify interobserver variability of CTV delineations, the total volume, craniocaudal, laterolateral, and anteroposterior diameters were calculated. Results: A total of 18 institutions for case A and 15 institutions for case B submitted the targets. Case A presented significant variability in total volume (range: 74.1-1,157.1 cc), craniocaudal (range: 6.5-22.5 cm; median: 16.25 cm), anteroposterior (range: 5.04-14.82 cm; median: 10.28 cm), and laterolateral diameters (range: 8.23-22.88 cm; median: 15.5 cm). Mean CTV was 464.8 cc (standard deviation: 280.5 cc). Case B presented significant variability in total volume (range: 341.8-1,662 cc), craniocaudal (range: 8.0-28.5 cm; median: 23 cm), anteroposterior (range: 7.9-1.8 cm; median: 11.1 cm), and laterolateral diameters (range: 12.9-24.0 cm; median: 18.8 cm). Mean CTV was 926.0 cc (standard deviation: 445.7 cc). Conclusion: This significant variability confirms the need to apply specific guidelines to improve contouring uniformity in Hodgkin's lymphoma.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/680899
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 26
social impact