OBJECTIVE: To analyze the temperature increase in the implant, adjacent bone, procedure time, and roughness provided by different rotatory instruments in the implantoplasty procedure. MATERIAL AND METHODS: Three types of rotational instruments were used to evaluate the implant surface wear, divided according to their surface features: Group 1 (G1) diamond, Group 2 (G2) tungsten carbide, and Group 3 (G3) multilaminar. For the roughness test, a control group was included for comparison with the test groups. RESULTS: The temperature variation was statistically significant in the implant (P < 0.05) where G2 showed the lowest variation. There was no statistically significant difference between the 3 groups regarding the temperature increase measured in the bone (P > 0.05). The difference of wear time was statistically significant (P < 0.05) with faster results for G3. In the surface roughness analyses, there was a statistically significant difference (P < 0.05) between the control group and the test groups. Among the 3 test groups, the difference between measurements was not statistically significant (P > 0.05).

Analysis of effectiveness of different rotational instruments in implantoplasty: An in vitro study

Iaculli F.;Piattelli A.;
2016-01-01

Abstract

OBJECTIVE: To analyze the temperature increase in the implant, adjacent bone, procedure time, and roughness provided by different rotatory instruments in the implantoplasty procedure. MATERIAL AND METHODS: Three types of rotational instruments were used to evaluate the implant surface wear, divided according to their surface features: Group 1 (G1) diamond, Group 2 (G2) tungsten carbide, and Group 3 (G3) multilaminar. For the roughness test, a control group was included for comparison with the test groups. RESULTS: The temperature variation was statistically significant in the implant (P < 0.05) where G2 showed the lowest variation. There was no statistically significant difference between the 3 groups regarding the temperature increase measured in the bone (P > 0.05). The difference of wear time was statistically significant (P < 0.05) with faster results for G3. In the surface roughness analyses, there was a statistically significant difference (P < 0.05) between the control group and the test groups. Among the 3 test groups, the difference between measurements was not statistically significant (P > 0.05).
File in questo prodotto:
File Dimensione Formato  
IMPLANTOPLASTY IMPLANT DENT.pdf

Solo gestori archivio

Tipologia: Documento in Post-print
Dimensione 566.26 kB
Formato Adobe PDF
566.26 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/706197
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 19
social impact