PURPOSE: The aim of the present histological and biomechanical analysis was to compare, in vivo, the strength and quality of osseointegration between a laser-treated implant surface and a standard machined surface. MATERIAL AND METHODS: Customized titanium implants, having 2 different surfaces, were used. Implants were longitudinally split in the 2 surfaces: one side was laser treated and the opposite one had a machined surface. Eight implants were inserted in the iliac crest of 2 sheep: 4 with a split laser and machined surfaces, 2 with a completely laser-treated surface, and 2 with fully machined surfaces. The animals were killed 8 weeks after the placement of implants. The histomorphometric and biomechanical parameters calculated for each surface were the bone-implant contact (%BIC) and the reverse torque value (RTV) RESULTS:: The RTV of the laser-treated implants were about 3-fold higher than that of the machined implants. The histomorphometric results showed a significant difference of %BIC around 30% between the laser surfaces compared to the machined ones.

Laser-Treated Titanium Implants: An in Vivo Histomorphometric and Biomechanical Analysis

Perfetti G.
2016-01-01

Abstract

PURPOSE: The aim of the present histological and biomechanical analysis was to compare, in vivo, the strength and quality of osseointegration between a laser-treated implant surface and a standard machined surface. MATERIAL AND METHODS: Customized titanium implants, having 2 different surfaces, were used. Implants were longitudinally split in the 2 surfaces: one side was laser treated and the opposite one had a machined surface. Eight implants were inserted in the iliac crest of 2 sheep: 4 with a split laser and machined surfaces, 2 with a completely laser-treated surface, and 2 with fully machined surfaces. The animals were killed 8 weeks after the placement of implants. The histomorphometric and biomechanical parameters calculated for each surface were the bone-implant contact (%BIC) and the reverse torque value (RTV) RESULTS:: The RTV of the laser-treated implants were about 3-fold higher than that of the machined implants. The histomorphometric results showed a significant difference of %BIC around 30% between the laser surfaces compared to the machined ones.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/707042
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact