In the present study, we tested the ability of VI-RADS score to discern MIBC from NMIBC. We found that the VI- RADS score has high accuracy. Thus, its routine use may be appealing. Background: The Vesical Imaging Reporting and Data System (VI-RADS) was recently introduced as a stan- dardized approach to reporting multiparametric magnetic resonance imaging (mpMRI) for bladder cancer. We aimed to prospectively analyze its routine use and its diagnostic performance in discriminating nonemuscle- invasive bladder cancer (NMIBC) and muscle-invasive bladder cancer (MIBC). Patients and Methods: A total of 38 patients with diagnosis of suspect bladder cancer at cystoscopy underwent bladder mpMRI before transurethral resection of the bladder (TURB). Bladder tumors were categorized according to the VI-RADS. After TURB, the VI- RADS score was compared with histological report for each lesion separately. Receiving operating characteristic and decision curve analyses were used to assess its accuracy and clinical utility. Results: A total of 68 lesions were included, of which 7 (10.3%) were MIBC. The pooled accuracy was 90.0% (95% confidence interval [CI], 75.4%- 98.7%). The best threshold was estimated as VI-RADS 4, showing a sensitivity of 85.7% (95% CI, 57.1%-100%) and a specificity of 86.9% (95% CI, 78.7%-95.1%). Decision curve analyses showed that using VI-RADS !4 improved the net benefit compared with any default strategy for threshold probabilities of MIBC up to w40%, which is a reasonable clinical threshold for planning further treatments. Conclusions: Our prospective study shows that the use of VI-RADS as a standardized reporting method is appealing and could be considered in clinical practice owing to its high accuracy.
Titolo: | Could Bladder Multiparametric MRI Be Introduced in Routine Clinical Practice? Role of the New VI-RADS Score: Results From a Prospective Study |
Autori: | |
Data di pubblicazione: | 2020 |
Rivista: | |
Abstract: | In the present study, we tested the ability of VI-RADS score to discern MIBC from NMIBC. We found that the VI- RADS score has high accuracy. Thus, its routine use may be appealing. Background: The Vesical Imaging Reporting and Data System (VI-RADS) was recently introduced as a stan- dardized approach to reporting multiparametric magnetic resonance imaging (mpMRI) for bladder cancer. We aimed to prospectively analyze its routine use and its diagnostic performance in discriminating nonemuscle- invasive bladder cancer (NMIBC) and muscle-invasive bladder cancer (MIBC). Patients and Methods: A total of 38 patients with diagnosis of suspect bladder cancer at cystoscopy underwent bladder mpMRI before transurethral resection of the bladder (TURB). Bladder tumors were categorized according to the VI-RADS. After TURB, the VI- RADS score was compared with histological report for each lesion separately. Receiving operating characteristic and decision curve analyses were used to assess its accuracy and clinical utility. Results: A total of 68 lesions were included, of which 7 (10.3%) were MIBC. The pooled accuracy was 90.0% (95% confidence interval [CI], 75.4%- 98.7%). The best threshold was estimated as VI-RADS 4, showing a sensitivity of 85.7% (95% CI, 57.1%-100%) and a specificity of 86.9% (95% CI, 78.7%-95.1%). Decision curve analyses showed that using VI-RADS !4 improved the net benefit compared with any default strategy for threshold probabilities of MIBC up to w40%, which is a reasonable clinical threshold for planning further treatments. Conclusions: Our prospective study shows that the use of VI-RADS as a standardized reporting method is appealing and could be considered in clinical practice owing to its high accuracy. |
Handle: | http://hdl.handle.net/11564/718316 |
Appare nelle tipologie: | 1.1 Articolo in rivista |
File in questo prodotto:
File | Descrizione | Tipologia | Licenza | |
---|---|---|---|---|
VIRADS Marchioni 1-s2.0-S1558767320300513-main.pdf | Documento in Post-print | Administrator Richiedi una copia |