Dual curecomposites contain both chemically and light-induced polymerization initiators, taking advantage of both processes; however, some studies have suggested that in order to obtain a complete polymerization of the sample it is necessary to light activate the material. Indeed, there is controversy in the literature about the effective polymerization of dual composites in deeper cavity, where light can be strongly attenuated. On the other hand, other studies hypothesized that light activation could determine a rapid increment of the viscosity of the material, blocking the movement of free radicals and avoiding a perfect polymerization. The aim of this study is to evaluate through the thermal analysis and thermogravimetry if dual composite samples, cured only by chemical reaction for 1h at body temperature of 37 degrees C, are characterized by the same properties of samples light cured for 40s at room temperature. The thermogravimetric curve (TGA), the differential thermal analysis and the first derivative of loss of mass (DTG) have been analyzed. The average temperature at which 5% of mass loss occurred and the percentage of the average mass loss between 250 and 350 degrees C have been recorded. Results have shown that both groups were characterized by a similar thermal stability, compatible with a good polymerization degree and no statistically significant differences have been found.

Dual cure composites: Could body temperature offset the absence of light activation?

Petrini M.
Primo
;
Spoto G.
Ultimo
2019-01-01

Abstract

Dual curecomposites contain both chemically and light-induced polymerization initiators, taking advantage of both processes; however, some studies have suggested that in order to obtain a complete polymerization of the sample it is necessary to light activate the material. Indeed, there is controversy in the literature about the effective polymerization of dual composites in deeper cavity, where light can be strongly attenuated. On the other hand, other studies hypothesized that light activation could determine a rapid increment of the viscosity of the material, blocking the movement of free radicals and avoiding a perfect polymerization. The aim of this study is to evaluate through the thermal analysis and thermogravimetry if dual composite samples, cured only by chemical reaction for 1h at body temperature of 37 degrees C, are characterized by the same properties of samples light cured for 40s at room temperature. The thermogravimetric curve (TGA), the differential thermal analysis and the first derivative of loss of mass (DTG) have been analyzed. The average temperature at which 5% of mass loss occurred and the percentage of the average mass loss between 250 and 350 degrees C have been recorded. Results have shown that both groups were characterized by a similar thermal stability, compatible with a good polymerization degree and no statistically significant differences have been found.
File in questo prodotto:
File Dimensione Formato  
Petrini2019_Article_DualCureCompositesCouldBodyTem.pdf

Solo gestori archivio

Descrizione: Article
Tipologia: PDF editoriale
Dimensione 592.74 kB
Formato Adobe PDF
592.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Dual-cured composites final 2 revision.doc

accesso aperto

Tipologia: Documento in Pre-print
Dimensione 85.5 kB
Formato Microsoft Word
85.5 kB Microsoft Word Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/745987
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact