Therapeutic drug monitoring (TDM) of antiseizure medications (ASMs) represents a valuable tool to establish an appropriate patient therapy, to collect important information about drugs’interactions and to evaluate patient’s metabolic capabilities. In recent years, a new volumetric absorptive microsampling technique using VAMS® technology and Mitra® devices, consisting of a sampling technique for the collection of fixed-volume capillary blood, was developed. These new devices provide a new home-sampling technique for whole blood that has been spread out to simplify sample collection from finger-pricks. This review is aimed to compare published articles concerning the application of VAMS® in epilepsy and to identify the strengths and improvement points for the TDM of antiseizure medications. VAMS® allowed a minimally invasive blood sampling even in the absence of trained personnel. Good stability data have indicated that storage and delivery can be facilitated only for specific ASMs. Trueness and precision parameters have been evaluated, and the hematocrit (HCT) effect was minimized.

Therapeutic drug monitoring of antiseizure medications using volumetric absorptive microsampling: where are we?

M. Locatelli;A. Tartaglia;C. D'Ovidio;
2021-01-01

Abstract

Therapeutic drug monitoring (TDM) of antiseizure medications (ASMs) represents a valuable tool to establish an appropriate patient therapy, to collect important information about drugs’interactions and to evaluate patient’s metabolic capabilities. In recent years, a new volumetric absorptive microsampling technique using VAMS® technology and Mitra® devices, consisting of a sampling technique for the collection of fixed-volume capillary blood, was developed. These new devices provide a new home-sampling technique for whole blood that has been spread out to simplify sample collection from finger-pricks. This review is aimed to compare published articles concerning the application of VAMS® in epilepsy and to identify the strengths and improvement points for the TDM of antiseizure medications. VAMS® allowed a minimally invasive blood sampling even in the absence of trained personnel. Good stability data have indicated that storage and delivery can be facilitated only for specific ASMs. Trueness and precision parameters have been evaluated, and the hematocrit (HCT) effect was minimized.
File in questo prodotto:
File Dimensione Formato  
pharmaceuticals-1211652.pdf

accesso aperto

Dimensione 639.6 kB
Formato Adobe PDF
639.6 kB Adobe PDF Visualizza/Apri
pharmaceuticals-14-00627.pdf

Solo gestori archivio

Dimensione 515.89 kB
Formato Adobe PDF
515.89 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/755101
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact