The first perioperative transesophageal echocardiography (TEE) guidelines published 21 years ago were mainly addressed to cardiac anesthesiologists. TEE has since expanded its role outside this setting and currently represents an invaluable tool to assess chamber sizes, ventricular hypertrophy, and systolic, diastolic, and valvular function in patients undergoing orthotopic liver transplantation (OLT). Right-sided microemboli, right ventricular dysfunction, and patent foramen ovale (PFO) are the most common intra-operative findings described during OLT. However, left ventricular outflow tract obstruction and left ventricular ballooning syndrome are more difficult to recognize and less frequent. Transesophageal ultrasonography (TEU) during OLT is also underused. Its applications are as follows: (1) assistance in the difficult placement of pulmonary arterial catheters; (2) help with catheterization of great vessels for external veno-venous bypass placement; (3) intra-operative evaluation of surgical liver anastomosis patency, if feasible, through the liver window; and (4) intra-operative investigation of "acute hypoxemia" due to pulmonary and cardiac issues using trans-esophageal lung ultrasound (TELU). The aims of this review are as follows: (1) to summarize the uses of TEE and TEU throughout all phases of OLT, and (2) to describe other new feasible applications.

Transesophageal ultrasonography during orthotopic liver transplantation: Show me more

Vetrugno L.
;
2018-01-01

Abstract

The first perioperative transesophageal echocardiography (TEE) guidelines published 21 years ago were mainly addressed to cardiac anesthesiologists. TEE has since expanded its role outside this setting and currently represents an invaluable tool to assess chamber sizes, ventricular hypertrophy, and systolic, diastolic, and valvular function in patients undergoing orthotopic liver transplantation (OLT). Right-sided microemboli, right ventricular dysfunction, and patent foramen ovale (PFO) are the most common intra-operative findings described during OLT. However, left ventricular outflow tract obstruction and left ventricular ballooning syndrome are more difficult to recognize and less frequent. Transesophageal ultrasonography (TEU) during OLT is also underused. Its applications are as follows: (1) assistance in the difficult placement of pulmonary arterial catheters; (2) help with catheterization of great vessels for external veno-venous bypass placement; (3) intra-operative evaluation of surgical liver anastomosis patency, if feasible, through the liver window; and (4) intra-operative investigation of "acute hypoxemia" due to pulmonary and cardiac issues using trans-esophageal lung ultrasound (TELU). The aims of this review are as follows: (1) to summarize the uses of TEE and TEU throughout all phases of OLT, and (2) to describe other new feasible applications.
2018
Inglese
35
8
1204
1215
12
Anesthesia; Hypovolemia; Intra-operative transesophageal echocardiography; Right ventricular function; Transesophageal echocardiography; Radiology; Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
https://onlinelibrary.wiley.com/doi/10.1111/echo.14037
no
8
info:eu-repo/semantics/article
262
Vetrugno, L.; Barnariol, F.; Bignami, E.; Centonze, G. D.; De Flaviis, A.; Piccioni, F.; Auci, E.; Bove, T
1 Contributo su Rivista::1.1 Articolo in rivista
reserved
File in questo prodotto:
File Dimensione Formato  
Transesophageal ultrasonography during orthotopic liver transplantation.pdf

Solo gestori archivio

Descrizione: Review
Tipologia: PDF editoriale
Dimensione 1.7 MB
Formato Adobe PDF
1.7 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/763615
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 20
social impact