Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.

From bench to bedside: Impact of left ventricular assist device outflow conduit anastomosis position on outcome

Gabriele Di Giammarco
Secondo
;
2021-01-01

Abstract

Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.
File in questo prodotto:
File Dimensione Formato  
aor.13809.pdf

Solo gestori archivio

Descrizione: Articolo principale accettato per la pubblicazione
Tipologia: Documento in Post-print
Dimensione 423.33 kB
Formato Adobe PDF
423.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Artificial Organs - 2020 - Tarzia - From bench to bedside Impact of left ventricular assist device outflow conduit.pdf

Solo gestori archivio

Tipologia: PDF editoriale
Dimensione 638.06 kB
Formato Adobe PDF
638.06 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/767431
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact