Background: Zygomatic implants have been proposed in literature for atrophic maxillary fixed oral rehabilitations. The aim of the present research was to evaluate, by a clinical and tomography assessment, a surgical complication of a zygomatic implant penetration to the orbit. Case presentation: A 56 year-old female patient was visited for pain and swelling in the left orbit after a zygomatic implant protocol. The orbit invasion of the zygomatic implant screw was confirmed by the CBCT scan. The patient was treated for surgical implant removal and the peri- and post-operative symptoms were assessed. No neurological complications were reported at the follow-up. The ocular motility and the visual acuity were well maintained. No purulent secretion or inflammatory evidence were reported in the post-operative healing phases. Conclusion: The penetration of the orbit during a zygomatic implant positioning is a surgical complication that could compromise the sight and movements of the eye. In the present case report, a zygomatic implant removal resulted in an uneventful healing phase with recovery of the eye functions.
Zygomatic implant penetration to the central portion of orbit: a case report
Lorusso F.;Scarano A.
2021-01-01
Abstract
Background: Zygomatic implants have been proposed in literature for atrophic maxillary fixed oral rehabilitations. The aim of the present research was to evaluate, by a clinical and tomography assessment, a surgical complication of a zygomatic implant penetration to the orbit. Case presentation: A 56 year-old female patient was visited for pain and swelling in the left orbit after a zygomatic implant protocol. The orbit invasion of the zygomatic implant screw was confirmed by the CBCT scan. The patient was treated for surgical implant removal and the peri- and post-operative symptoms were assessed. No neurological complications were reported at the follow-up. The ocular motility and the visual acuity were well maintained. No purulent secretion or inflammatory evidence were reported in the post-operative healing phases. Conclusion: The penetration of the orbit during a zygomatic implant positioning is a surgical complication that could compromise the sight and movements of the eye. In the present case report, a zygomatic implant removal resulted in an uneventful healing phase with recovery of the eye functions.File | Dimensione | Formato | |
---|---|---|---|
s12886-021-01846-1.pdf
accesso aperto
Descrizione: Case Report
Tipologia:
PDF editoriale
Dimensione
4.02 MB
Formato
Adobe PDF
|
4.02 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.