Objectives: Intrauterine growth restriction (IUGR) represents one of the main causes of perinatal mortality and morbidity. Nowadays, IUGR early diagnosis is mandatory in order to limit the occurrence of multiorgan failure, especially the brain. Therefore, we investigated whether longitudinal S100B assessment in maternal blood could be a trustable predictor of IUGR. Methods: We conducted a prospective study in 480 pregnancies (IUGR: n=40; small for gestational age, SGA: n=40; controls: n=400) in whom S100B was measured at three predetermined monitoring time-points (T1: 8-18 GA; T2: 19-23 GA; T3: 24-28 GA). Results: Lower S100B in IUGR fetuses than SGA and controls (p<0.05, for all) at T1-T3. Receiver operating characteristic curve showed that S100B at T1 was the best predictor of IUGR (sensitivity: 100 %; specificity: 81.4 %) than T2, T3. Conclusions: The early lower S100B concentration in pregnant women lately complicated by IUGR support the notion that non-invasive early IUGR diagnosis and monitoring is becoming feasible. Results open the way to further studies aimed at diagnosing and monitoring fetal/maternal diseases at earliest time.
Early changes in S100B maternal blood levels can predict fetal intrauterine growth restriction
D'Adamo, Ebe;Botondi, Valentina;Patacchiola, Roberta;Librandi, Michela;Osmelli, Jacopo;Carabotta, Maura;Chiarelli, Francesco;Gazzolo, Diego
2023-01-01
Abstract
Objectives: Intrauterine growth restriction (IUGR) represents one of the main causes of perinatal mortality and morbidity. Nowadays, IUGR early diagnosis is mandatory in order to limit the occurrence of multiorgan failure, especially the brain. Therefore, we investigated whether longitudinal S100B assessment in maternal blood could be a trustable predictor of IUGR. Methods: We conducted a prospective study in 480 pregnancies (IUGR: n=40; small for gestational age, SGA: n=40; controls: n=400) in whom S100B was measured at three predetermined monitoring time-points (T1: 8-18 GA; T2: 19-23 GA; T3: 24-28 GA). Results: Lower S100B in IUGR fetuses than SGA and controls (p<0.05, for all) at T1-T3. Receiver operating characteristic curve showed that S100B at T1 was the best predictor of IUGR (sensitivity: 100 %; specificity: 81.4 %) than T2, T3. Conclusions: The early lower S100B concentration in pregnant women lately complicated by IUGR support the notion that non-invasive early IUGR diagnosis and monitoring is becoming feasible. Results open the way to further studies aimed at diagnosing and monitoring fetal/maternal diseases at earliest time.File | Dimensione | Formato | |
---|---|---|---|
10.1515_cclm-2023-0294 (1).pdf
Solo gestori archivio
Tipologia:
PDF editoriale
Dimensione
434.03 kB
Formato
Adobe PDF
|
434.03 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.