Objectives: The aim of the present human observational study is to provide morphologic and morphometric analysis of peri-implant connective tissue next to abutments with divergent or convergent macro-geometry and different surface micro-characteristics.Materials and Methods: Thirty patients were rehabilitated with single implants in the posterior area and one out of three different healing abutments with a one-stage technique: machined divergent abutment (DIV-MAC), machined convergent abutment (CONV-MAC) or convergent abutment with ultrathin threaded surface (CONV-UTM). At 3 months postimplant insertion, peri-implant soft tissue was harvested; the following outcomes were investigated: histomorphometry (vertical width of connective and epithelial components) as detected by histology and polarized light; and connective tissue vertical width and 3D organization as detected by synchrotron-based high-resolution phase-contrast-based tomography (PhC-mu CT).Results: Significant differences in connective tissue vertical dimension (aJE-AM) were found between DIV-MAC and both CONV-MAC and CONV-UTM, both by histology and PhC-mu CT, with significantly higher values for the last two groups. Moreover, 2D histological analysis did not find significant differences in the junctional epithelium vertical dimension (PM-aJE). Importantly, PhC-mu CT analysis revealed, at 3D level, significant greater amount and density of collagen bundles for CONV-UTM compared with the other two groups.Conclusions: Convergent abutment profiles, regardless of their surface micro-geometry, seem to favor axial development of peri-implant connective tissue. Moreover, ultrathin threaded surfaces seem associated with denser and greater connective tissue organization, which might improve peri-implant soft tissue seal.

Influence of abutment macro- and micro-geometry on morphologic and morphometric features of peri-implant connective tissue

Piattelli, Adriano;Iezzi, Giovanna
Ultimo
2023-01-01

Abstract

Objectives: The aim of the present human observational study is to provide morphologic and morphometric analysis of peri-implant connective tissue next to abutments with divergent or convergent macro-geometry and different surface micro-characteristics.Materials and Methods: Thirty patients were rehabilitated with single implants in the posterior area and one out of three different healing abutments with a one-stage technique: machined divergent abutment (DIV-MAC), machined convergent abutment (CONV-MAC) or convergent abutment with ultrathin threaded surface (CONV-UTM). At 3 months postimplant insertion, peri-implant soft tissue was harvested; the following outcomes were investigated: histomorphometry (vertical width of connective and epithelial components) as detected by histology and polarized light; and connective tissue vertical width and 3D organization as detected by synchrotron-based high-resolution phase-contrast-based tomography (PhC-mu CT).Results: Significant differences in connective tissue vertical dimension (aJE-AM) were found between DIV-MAC and both CONV-MAC and CONV-UTM, both by histology and PhC-mu CT, with significantly higher values for the last two groups. Moreover, 2D histological analysis did not find significant differences in the junctional epithelium vertical dimension (PM-aJE). Importantly, PhC-mu CT analysis revealed, at 3D level, significant greater amount and density of collagen bundles for CONV-UTM compared with the other two groups.Conclusions: Convergent abutment profiles, regardless of their surface micro-geometry, seem to favor axial development of peri-implant connective tissue. Moreover, ultrathin threaded surfaces seem associated with denser and greater connective tissue organization, which might improve peri-implant soft tissue seal.
File in questo prodotto:
File Dimensione Formato  
Clinical Oral Implants Res - 2023 - Canullo.pdf

accesso aperto

Tipologia: PDF editoriale
Dimensione 2.72 MB
Formato Adobe PDF
2.72 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/815531
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact