Background: In this study, we aimed to report the short-term (6 months) effects on visual functionality and safety of femto-laser assisted smaller-incision new-generation implantable miniature telescope (SING-IMT™) implanting, particularly related to postsurgical intraocular pressure increase, in patients suffering from end-stage age-related macular degeneration (AMD) and cataract. This device, designed for monocular use, aims to minimise the impact of the central scotoma by projecting the images onto a larger area of the photoreceptors surrounding the macula. Methods: In this prospective multicentric observational case series study, 6 eyes of 6 patients who underwent SINGIMT™ implantations were enrolled. At baseline and 6 months follow-up, best corrected distance visual acuity (BCDV) and best corrected near visual acuity (BCNVA), intraocular pressure (IOP), anterior chamber depth, endothelial cells count were assessed. In addition, IOP was also measured at 7, 15, 30, 45 days, and at 3 months follow-up. Finally, the incidence of complications was evaluated. Results: At final follow-up, in the study eyes, mean BCDVA improved by +10.0 letters (6.25; 13.8) letters and mean BCNVA improved by −0.30 logMAR (−0.55; −0.20). At postoperative month 6, we reported a mean IOP decrease of 4.50 mmHg (−5.75; −0.25). Interestingly, 83.3% of patients had an increased IOP value in at least one of the first two postoperative follow-ups (7 days and 15 days). In patients in whom intraoperative mechanical iridotomy was not performed, it was necessary to perform a postoperative YAG laser iridotomy to improve IOP management. Compared to the baseline, ECD loss at 6 months follow-up was 12.6%. Conclusions: The SING IMT™ device was found to be effective in the distance and near vision improvement, without serious postoperative complications. We recommend intraoperative mechanical iridectomy in order to easily manage post-operative IOP and to avoid sudden IOP rise with its possible consequences. These good results can be a hope to partially improve the quality of life of patients suffering from severe end stage macular atrophy

Intraoperative Iridectomy in Femto-Laser Assisted Smaller-Incision New Generation Implantable Miniature Telescope

Mastropasqua, Rodolfo;Gironi, Matteo;D’Aloisio, Rossella;Vecchiarino, Luca;Porreca, Annamaria;Di Nicola, Marta;
2024-01-01

Abstract

Background: In this study, we aimed to report the short-term (6 months) effects on visual functionality and safety of femto-laser assisted smaller-incision new-generation implantable miniature telescope (SING-IMT™) implanting, particularly related to postsurgical intraocular pressure increase, in patients suffering from end-stage age-related macular degeneration (AMD) and cataract. This device, designed for monocular use, aims to minimise the impact of the central scotoma by projecting the images onto a larger area of the photoreceptors surrounding the macula. Methods: In this prospective multicentric observational case series study, 6 eyes of 6 patients who underwent SINGIMT™ implantations were enrolled. At baseline and 6 months follow-up, best corrected distance visual acuity (BCDV) and best corrected near visual acuity (BCNVA), intraocular pressure (IOP), anterior chamber depth, endothelial cells count were assessed. In addition, IOP was also measured at 7, 15, 30, 45 days, and at 3 months follow-up. Finally, the incidence of complications was evaluated. Results: At final follow-up, in the study eyes, mean BCDVA improved by +10.0 letters (6.25; 13.8) letters and mean BCNVA improved by −0.30 logMAR (−0.55; −0.20). At postoperative month 6, we reported a mean IOP decrease of 4.50 mmHg (−5.75; −0.25). Interestingly, 83.3% of patients had an increased IOP value in at least one of the first two postoperative follow-ups (7 days and 15 days). In patients in whom intraoperative mechanical iridotomy was not performed, it was necessary to perform a postoperative YAG laser iridotomy to improve IOP management. Compared to the baseline, ECD loss at 6 months follow-up was 12.6%. Conclusions: The SING IMT™ device was found to be effective in the distance and near vision improvement, without serious postoperative complications. We recommend intraoperative mechanical iridectomy in order to easily manage post-operative IOP and to avoid sudden IOP rise with its possible consequences. These good results can be a hope to partially improve the quality of life of patients suffering from severe end stage macular atrophy
File in questo prodotto:
File Dimensione Formato  
jcm-13-00076-v2.pdf

accesso aperto

Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/821851
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact