Preimplantation genetic diagnosis and aneuploidy testing (PGD/PGS) use is constantly growing in IVF, and embryo/biopsy traceability during the additional laboratory procedures needed is pivotal. An electronic witnessing system (EWS), which showed a significant value in decreasing mismatch occurrence and increasing detection possibilities during standard care IVF, still does not guarantee the same level of efficiency during PGD/PGS cycles. Specifically, EWS cannot follow single embryos throughout the procedure. This is however critical when an unambiguous diagnosis corresponds to each embryo. Failure Mode and Effects Analysis (FMEA) is a proactive method generally adopted to define tools ensuring safety along a procedure. Due to the implementation of a large quantitative PCR (qPCR)-based blastocyst stage PGD/PGS programme in our centre, and to evaluate the potential procedural risks, a FMEA was performed in September 2014. Forty-four failure modes were identified, among which six were given a moderate risk priority number (>15) (RPN; product of estimated occurrence, severity and detection). Specific corrective measures were then introduced and implemented, and a second evaluation performed six months later. The meticulous and careful application of such measures allowed the risks to be decreased along the whole protocol, by reducing their estimated occurrence and/or increasing detection possibilities. (C) 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
Failure mode and effects analysis of witnessing protocols for ensuring traceability during PGD/PGS cycles
Capalbo, Antonio;
2016-01-01
Abstract
Preimplantation genetic diagnosis and aneuploidy testing (PGD/PGS) use is constantly growing in IVF, and embryo/biopsy traceability during the additional laboratory procedures needed is pivotal. An electronic witnessing system (EWS), which showed a significant value in decreasing mismatch occurrence and increasing detection possibilities during standard care IVF, still does not guarantee the same level of efficiency during PGD/PGS cycles. Specifically, EWS cannot follow single embryos throughout the procedure. This is however critical when an unambiguous diagnosis corresponds to each embryo. Failure Mode and Effects Analysis (FMEA) is a proactive method generally adopted to define tools ensuring safety along a procedure. Due to the implementation of a large quantitative PCR (qPCR)-based blastocyst stage PGD/PGS programme in our centre, and to evaluate the potential procedural risks, a FMEA was performed in September 2014. Forty-four failure modes were identified, among which six were given a moderate risk priority number (>15) (RPN; product of estimated occurrence, severity and detection). Specific corrective measures were then introduced and implemented, and a second evaluation performed six months later. The meticulous and careful application of such measures allowed the risks to be decreased along the whole protocol, by reducing their estimated occurrence and/or increasing detection possibilities. (C) 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S147264831630373X-main.pdf
Solo gestori archivio
Tipologia:
PDF editoriale
Dimensione
1.31 MB
Formato
Adobe PDF
|
1.31 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.