Abstract: Due to a great demand for amylose and cellulose polymeric chromatographic chiral columns, the enantiomeric separation of thiourea derivatives of naringenin was achieved on the different amylose (Chiralpak-IB) and cellulose chiral (Chiralcel-OJ and Chiralcel-OD-3R) columns with varied chromatographic conditions. The isocratic mobile phases used were ethanol and methanol, where ethanol/hexane and methanol/hexane were used as gradient mode and were prepared in volume/volume relation. The separation and resolution factors for all the enantiomers were in the range of, 1.25 to 3.47 and 0.48 to 1.75, respectively. The enantiomeric resolution was obtained within 12 minutes making fast separation. The docking studies confirmed the chiral recognition mechanisms with binding affinities in the range of -4.7 to -5.7 Kcal/mol. The reported compounds have good anti- coagulant activities and may be used as anti-coagulants in the future. Besides, chiral separation is fast and is useful for enantiomeric separation in any laboratory in the world.
Enantiomeric separation of thiourea derivatives of naringenin on amylose and cellulose polymeric chromatographic chiral columns
Marcello Locatelli;
2024-01-01
Abstract
Abstract: Due to a great demand for amylose and cellulose polymeric chromatographic chiral columns, the enantiomeric separation of thiourea derivatives of naringenin was achieved on the different amylose (Chiralpak-IB) and cellulose chiral (Chiralcel-OJ and Chiralcel-OD-3R) columns with varied chromatographic conditions. The isocratic mobile phases used were ethanol and methanol, where ethanol/hexane and methanol/hexane were used as gradient mode and were prepared in volume/volume relation. The separation and resolution factors for all the enantiomers were in the range of, 1.25 to 3.47 and 0.48 to 1.75, respectively. The enantiomeric resolution was obtained within 12 minutes making fast separation. The docking studies confirmed the chiral recognition mechanisms with binding affinities in the range of -4.7 to -5.7 Kcal/mol. The reported compounds have good anti- coagulant activities and may be used as anti-coagulants in the future. Besides, chiral separation is fast and is useful for enantiomeric separation in any laboratory in the world.File | Dimensione | Formato | |
---|---|---|---|
Chirality accepted.pdf
accesso aperto
Descrizione: S
Dimensione
763.82 kB
Formato
Adobe PDF
|
763.82 kB | Adobe PDF | Visualizza/Apri |
Chirality 2024.pdf
Solo gestori archivio
Tipologia:
PDF editoriale
Dimensione
3.7 MB
Formato
Adobe PDF
|
3.7 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.