Peritoneal dialysis (PD) is a home-based efficacious modality for the replacement of renal function in end-stage kidney failure patients, but it is still under-prescribed. A major limitation is the durability of the dialytic technique. Continuous exposure of the peritoneum to bioincompatible conventional glucose-based solutions is thought to be the main cause of the long-term morphofunctional peritoneal changes that eventually result in ultrafiltration failure. Poor PD solution biocompatibility is primarily related to the high glucose content, which is not only detrimental to the peritoneal membrane but has many potential metabolic side effects. To improve the clinical outcome and prolong the survival of the treatment, PD-related bioincompatibility urgently needs to be overcome. However, combining dialytic and osmotic efficacy with a satisfactory biocompatible profile is proving to be quite difficult. New approaches targeting the composition of the PD solution include the replacement of glucose with other osmotic agents, and the addition of cytoprotective or osmo-metabolic compounds. Other strategies include the infusion of mesenchymal cells or the administration of orally active agents. In the present article, we review the current evidence on efforts to improve the biocompatible and functional performance of PD, focusing on studies performed in vivo (animal models of PD, human subjects on PD).

Coupling Osmotic Efficacy with Biocompatibility in Peritoneal Dialysis: A Stiff Challenge

Bonomini Mario
Primo
;
Sirolli Vittorio;Di Liberato Lorenzo;Arduini Arduino
Ultimo
2024-01-01

Abstract

Peritoneal dialysis (PD) is a home-based efficacious modality for the replacement of renal function in end-stage kidney failure patients, but it is still under-prescribed. A major limitation is the durability of the dialytic technique. Continuous exposure of the peritoneum to bioincompatible conventional glucose-based solutions is thought to be the main cause of the long-term morphofunctional peritoneal changes that eventually result in ultrafiltration failure. Poor PD solution biocompatibility is primarily related to the high glucose content, which is not only detrimental to the peritoneal membrane but has many potential metabolic side effects. To improve the clinical outcome and prolong the survival of the treatment, PD-related bioincompatibility urgently needs to be overcome. However, combining dialytic and osmotic efficacy with a satisfactory biocompatible profile is proving to be quite difficult. New approaches targeting the composition of the PD solution include the replacement of glucose with other osmotic agents, and the addition of cytoprotective or osmo-metabolic compounds. Other strategies include the infusion of mesenchymal cells or the administration of orally active agents. In the present article, we review the current evidence on efforts to improve the biocompatible and functional performance of PD, focusing on studies performed in vivo (animal models of PD, human subjects on PD).
File in questo prodotto:
File Dimensione Formato  
Copling osmotic efficacy IJMS 2024.pdf

accesso aperto

Tipologia: PDF editoriale
Dimensione 388.17 kB
Formato Adobe PDF
388.17 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/827932
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact