Trace-level monitoring of ciprofloxacin (CPRO) in aquatic environments is essential for managing antibiotic pollution and bacterial resistance. This study presents a cost-effective portable sensor that employs square-wave anodic stripping voltammetry (SWASV) at an unmodified glassy carbon electrode (GCE) operated in acetate buffer. Detailed optimization tests were performed with the aim of finding the best parameters for this purpose. In particular, deposition time and frequency were tested and all the analytical performance were verified. River-water recoveries attained concentrations obtained by HPLC-MS/MS, HPLC-DAD, and UV/Vis methods. On-site measurements agreed with laboratory analyses, validating field applicability. The protocol also quantified a commercial eye-drop formulation demonstrating applicability of system to pharmaceutical excipients. Overall, the SWASV-GCE method provides a robust, low-cost method for rapid in-situ determination of ciprofloxacin in environmental waters and pharmaceutical matrices. Additionally, a green profile evaluation by means of the recent tools was also addressed and discussed.

Portable Electrochemical Sensor for Trace Analysis of Ciprofloxacin in Water and Pharmaceutical Samples

Marcello Locatelli;
2025-01-01

Abstract

Trace-level monitoring of ciprofloxacin (CPRO) in aquatic environments is essential for managing antibiotic pollution and bacterial resistance. This study presents a cost-effective portable sensor that employs square-wave anodic stripping voltammetry (SWASV) at an unmodified glassy carbon electrode (GCE) operated in acetate buffer. Detailed optimization tests were performed with the aim of finding the best parameters for this purpose. In particular, deposition time and frequency were tested and all the analytical performance were verified. River-water recoveries attained concentrations obtained by HPLC-MS/MS, HPLC-DAD, and UV/Vis methods. On-site measurements agreed with laboratory analyses, validating field applicability. The protocol also quantified a commercial eye-drop formulation demonstrating applicability of system to pharmaceutical excipients. Overall, the SWASV-GCE method provides a robust, low-cost method for rapid in-situ determination of ciprofloxacin in environmental waters and pharmaceutical matrices. Additionally, a green profile evaluation by means of the recent tools was also addressed and discussed.
2025
Inglese
ELETTRONICO
218
1
9
9
article 115295
Ciprofloxacin; Voltammetry; Water; Emerging Contaminats; On-site analysis
no
8
info:eu-repo/semantics/article
262
Mazzoni, Letizia; Abollino, Ornella; Fabbri, Debora; Marafante, Matteo; Locatelli, Marcello; Perrucci, Miryam; Giacomino, Agnese; Inaudi, Paolo...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/863793
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact