Mortar joint reconstruction of exposed brick masonry is still performed manually, with limited repeatability. This paper presents an image-guided robotic workflow that converts a rectified photograph of a regular or quasi-regular face brick wall into an executable, extrusion-synchronized robot program. AI-based segmentation provides the mortar joint network, which graph-based path planning converts into an ordered deposition trajectory. The trajectory is verified through virtual commissioning, assigned a robot configuration by a multicriteria kinematic framework, and translated into synchronized robot code. Validation covered three levels: joint centre localization on 12 walls, with a 1.44 mm mean error, within half the 8 mm minimum joint width; path generation on 30 walls, with an 86.7% direct pass rate and full recovery after band adjustment; and physical execution on a planar laboratory specimen along 6750 mm of trajectory, with computation under 45 s. The workflow links image-based survey to robotic joint repair.
Image-guided robotic workflow for automated mortar joint reconstruction in regular and quasi-regular face brick masonry
Vecchi, Andrea
Primo
;Ricciutelli, AlessandroSecondo
;Sangiorgio, Valentino
Ultimo
2027-01-01
Abstract
Mortar joint reconstruction of exposed brick masonry is still performed manually, with limited repeatability. This paper presents an image-guided robotic workflow that converts a rectified photograph of a regular or quasi-regular face brick wall into an executable, extrusion-synchronized robot program. AI-based segmentation provides the mortar joint network, which graph-based path planning converts into an ordered deposition trajectory. The trajectory is verified through virtual commissioning, assigned a robot configuration by a multicriteria kinematic framework, and translated into synchronized robot code. Validation covered three levels: joint centre localization on 12 walls, with a 1.44 mm mean error, within half the 8 mm minimum joint width; path generation on 30 walls, with an 86.7% direct pass rate and full recovery after band adjustment; and physical execution on a planar laboratory specimen along 6750 mm of trajectory, with computation under 45 s. The workflow links image-based survey to robotic joint repair.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


