Purpose: The restoration of the normal joint line (JL) is important both in primary and revision total knee arthroplasty (TKA). However, the assessment of the femoro-tibial JL is still controversial. A strong correlation between femoral width (FW) and distance from adductor tubercle (AT) to JL was found on radiographs, with a ratio of 0.54. The hypothesis was that this ratio was applicable also in the surgical theatre by using measurements obtained intra-operatively with a caliper. Methods: Femoral width, AT to JL distance and the RATIO between AT to JL distance and FW of 40 patients who underwent TKA were measured on radiograph and intra-operatively. Bland–Altman agreement tests with repeated measurements and linear regression analysis were used. The ratio was used to estimate the distance between JL and AT. Results: The AT to JL distance/FW ratio calculated with linear regression resulted 0.54 for radiographic measurements and 0.53 for intra-operative measurements. There was no difference (0.009 ± 0.03) between the calculated ratios on radiographic and intra-operative measurements, and the correlation between intra-operative and radiographic measurements was 0.5 (p = 0.0016). Conclusions: This study shows that the validity of the radiographic method which uses an AT to JL distance/FW ratio to determine the level of the JL is confirmed also when using intra-operatively acquired measurements. Thus, this ratio represents a reliable tool to determine the JL level even in challenging prosthetic revision cases when the anatomical JL is missing. Level of evidence: Case series, Level IV. © 2013, Springer-Verlag Berlin Heidelberg.

The adductor tubercle as an important landmark to determine the joint line level in total knee arthroplasty: from radiographs to surgical theatre

D. Bruni;
2014-01-01

Abstract

Purpose: The restoration of the normal joint line (JL) is important both in primary and revision total knee arthroplasty (TKA). However, the assessment of the femoro-tibial JL is still controversial. A strong correlation between femoral width (FW) and distance from adductor tubercle (AT) to JL was found on radiographs, with a ratio of 0.54. The hypothesis was that this ratio was applicable also in the surgical theatre by using measurements obtained intra-operatively with a caliper. Methods: Femoral width, AT to JL distance and the RATIO between AT to JL distance and FW of 40 patients who underwent TKA were measured on radiograph and intra-operatively. Bland–Altman agreement tests with repeated measurements and linear regression analysis were used. The ratio was used to estimate the distance between JL and AT. Results: The AT to JL distance/FW ratio calculated with linear regression resulted 0.54 for radiographic measurements and 0.53 for intra-operative measurements. There was no difference (0.009 ± 0.03) between the calculated ratios on radiographic and intra-operative measurements, and the correlation between intra-operative and radiographic measurements was 0.5 (p = 0.0016). Conclusions: This study shows that the validity of the radiographic method which uses an AT to JL distance/FW ratio to determine the level of the JL is confirmed also when using intra-operatively acquired measurements. Thus, this ratio represents a reliable tool to determine the JL level even in challenging prosthetic revision cases when the anatomical JL is missing. Level of evidence: Case series, Level IV. © 2013, Springer-Verlag Berlin Heidelberg.
File in questo prodotto:
File Dimensione Formato  
The adductor tubercle as an important.pdf

Solo gestori archivio

Descrizione: Article
Tipologia: PDF editoriale
Dimensione 723.9 kB
Formato Adobe PDF
723.9 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/726559
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact