PURPOSE:The goal of this study was to compare three types of mobile-bearing posterior cruciate ligament (PCL)-sacrificing TKA. The hypothesis was that the three designs provide differences in flexion stability and femoral rollback and improved clinical score at 2-year follow-up.METHODS:Three groups of patients, divided according to implant design, were analysed retrospectively. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion and anterior drawer test at 90° flexion. WOMAC, KSS and SF36 scores were collected pre-operatively and at 2-year follow-up. RESULTS:There are no differences in kinematic or clinical performance of the three implants, except for the antero-posterior translation during stress test in flexion: only Cohort B had comparable pre- and post-operative laxity test values (p < 0.001). All three TKA designs allowed to maintain pre-operative tibial rotation pattern through all range of knee flexion. All clinical scores of the three patient cohorts were significantly improved post-operatively compared to the pre-operative values (p < 0.001). Moreover, we found no differences among post-operative results of the three designs. CONCLUSION:Despite design variations, mobile-bearing PCL-sacrificing TKA reproduces femoral rollback and screw-home with little or no difference in clinical or functional scores at a follow-up of 2 years. LEVEL OF EVIDENCE:III.

Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences

BRUNI, DANILO;
2014-01-01

Abstract

PURPOSE:The goal of this study was to compare three types of mobile-bearing posterior cruciate ligament (PCL)-sacrificing TKA. The hypothesis was that the three designs provide differences in flexion stability and femoral rollback and improved clinical score at 2-year follow-up.METHODS:Three groups of patients, divided according to implant design, were analysed retrospectively. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion and anterior drawer test at 90° flexion. WOMAC, KSS and SF36 scores were collected pre-operatively and at 2-year follow-up. RESULTS:There are no differences in kinematic or clinical performance of the three implants, except for the antero-posterior translation during stress test in flexion: only Cohort B had comparable pre- and post-operative laxity test values (p < 0.001). All three TKA designs allowed to maintain pre-operative tibial rotation pattern through all range of knee flexion. All clinical scores of the three patient cohorts were significantly improved post-operatively compared to the pre-operative values (p < 0.001). Moreover, we found no differences among post-operative results of the three designs. CONCLUSION:Despite design variations, mobile-bearing PCL-sacrificing TKA reproduces femoral rollback and screw-home with little or no difference in clinical or functional scores at a follow-up of 2 years. LEVEL OF EVIDENCE:III.
2014
Inglese
STAMPA
22
12
3113
3120
8
Antero-stabilized knee; Kinematics; Navigation; Postero-stabilized knee; Total knee arthroplasty; Aged; Aged; 80 and over; Arthroplasty; Replacement; Knee; Biomechanical Phenomena; Female; Femur; Humans; Joint Instability; Knee Prosthesis; Male; Middle Aged; Osteoarthritis; Knee; Posterior Cruciate Ligament; Range of Motion; Articular; Retrospective Studies; Rotation; Tibia; Orthopedics and Sports Medicine; Surgery; Medicine (all)
https://link.springer.com/article/10.1007/s00167-014-3200-5
8
info:eu-repo/semantics/article
262
Bignozzi, Simone; Zaffagnini, Stefano; Akkawi, Ibrahim; Marko, Tedi; Bruni, Danilo; Neri, MARIA PIA; Colle, Francesca; Marcacci, Maurilio
1 Contributo su Rivista::1.1 Articolo in rivista
reserved
File in questo prodotto:
File Dimensione Formato  
Bignozzi2014_Article_ThreeDifferentCruciate-sacrifi.pdf

Solo gestori archivio

Descrizione: Articolo principale
Tipologia: PDF editoriale
Dimensione 833 kB
Formato Adobe PDF
833 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11564/726700
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 15
social impact